Weitere Informationen und Metadaten
Konsolidierte Fassung vom 14.03.2022 · CELEX: 02020D1167-20220314
Rechtsstatus des zugrunde liegenden Rechtsakts laut EUR-Lex: In Kraft.
Gültig ab: 27.08.2020
Metadatenstand: 24.10.2026
02020D1167 — EN — 14.03.2022 — 002.001
This text is meant purely as a documentation tool and has no legal effect. The Union's institutions do not assume any liability for its contents. The authentic versions of the relevant acts, including their preambles, are those published in the Official Journal of the European Union and available in EUR-Lex. Those official texts are directly accessible through the links embedded in this document
|
►B |
COMMISSION IMPLEMENTING DECISION (EU) 2020/1167 of 6 August 2020 on the approval of the technology used in a 48 Volt efficient motor-generator combined with a 48 Volt/12 Volt DC/DC converter for use in conventional combustion engine and certain hybrid electric passenger cars and light commercial vehicles as an innovative technology pursuant to Regulation (EU) 2019/631 of the European Parliament and of the Council) (Text with EEA relevance) (OJ L 258 7.8.2020, p. 15) |
Amended by:
|
|
|
Official Journal | ||
|
No |
page |
date | ||
|
►M1 |
COMMISSION IMPLEMENTING DECISION (EU) 2021/488 of 22 March 2021 |
L 100 |
15 |
23.3.2021 |
|
►M2 |
COMMISSION IMPLEMENTING DECISION (EU) 2022/252 of 21 February 2022 |
L 41 |
33 |
22.2.2022 |
▼B
COMMISSION IMPLEMENTING DECISION (EU) 2020/1167
of 6 August 2020
on the approval of the technology used in a 48 Volt efficient motor-generator combined with a 48 Volt/12 Volt DC/DC converter for use in conventional combustion engine and certain hybrid electric passenger cars and light commercial vehicles as an innovative technology pursuant to Regulation (EU) 2019/631 of the European Parliament and of the Council)
(Text with EEA relevance)
Article 1
Innovative technology
The technology used in a 48 Volt efficient motor-generator combined with a 48 Volt/12 Volt DC/DC converter is approved as an innovative technology within the meaning of Article 11 of Regulation (EU) 2019/631 taking into account that the CO2 savings it delivers are only partially covered by the standard test procedure set out in Regulation (EU) 2017/1151, and provided that the technology conforms to the following:
▼M1
it is fitted in passenger cars (M1) or light commercial vehicles (N1) with the following characteristics:
vehicles powered by internal combustion engines (conventional ICE vehicles) capable of running on petrol, diesel, liquefied petroleum gas (LPG), compressed natural gas (CNG) or E85 or a combination of those fuels;
not-off-vehicle charging hybrid electric vehicles capable of running on the fuels referred to in point (i) for which uncorrected fuel consumption and CO2 emission values may be used in accordance with point 1.1.4 of Appendix 2 of Sub-Annex 8 to Annex XXI to Regulation (EU) 2017/1151.
▼B
its efficiency, which is the product of the efficiency of the 48 Volt motor-generator and the efficiency of the 48 Volt/12 Volt DC/DC converter, determined in accordance with point 2.3 of the Annex, is at least
▼M1
73,8 % for petrol- or E85-fuelled vehicles other than turbo-charged;
73,4 % for turbo-charged petrol- or E85-fuelled vehicles;
▼B
74,2 % for diesel-fuelled vehicles;
▼M1
74,6 % for LPG-fuelled vehicles other than turbo-charged;
74,1 % for turbo-charged LPG-fuelled vehicles;
76,3 % for CNG-fuelled vehicles other than turbo-charged;
75,7 % for turbo-charged CNG-fuelled vehicles.
▼B
Article 2
Application for certification of CO2 savings
Article 3
Certification of CO2 savings
▼M1
Where the innovative technology is fitted in a bi-fuel or flex-fuel vehicle, the type-approval authority shall record the certified CO2 savings as follows:
for a bi-fuel vehicle using petrol and gaseous fuels, the CO2 savings value with regard to LPG or CNG;
for a flex-fuel vehicle using petrol and E85, the CO2 savings value with regard to petrol.
▼B
Article 4
Eco-innovation code
Article 5
Entry into force
This Decision shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.
ANNEX
Methodology to determine the CO2 savings of the technology used in a 48 Volt efficient motor-generator combined with a 48 Volt/12 Volt DC/DC converter for conventional combustion engine and certain hybrid electric passenger cars and light commercial vehicles
1. INTRODUCTION
This Annex sets out the methodology to determine the CO2 (carbon dioxide) emission savings from the use of a 48 Volt efficient motor-generator (‘48V motor-generator’), combined with a 48 Volt/12 Volt DC/DC converter ‘48V/12V DC/DC converter’), in an M1 or N1 vehicle as specified in Article 1(a)).
2. DETERMINATION OF THE EFFICIENCIES
The efficiency of the 48V motor-generator and the 48V/12V DC/DC converter is to be determined separately as specified in points 2.1 and 2.2. The resulting values are to be used as input for the calculation of the total efficiency of the 48V motor-generator combined with the 48V/12V DC/DC converter in accordance with point 2.3.
2.1. 48V motor-generator efficiency
The efficiency of the 48V motor-generator shall be determined in accordance with ISO 8854:2012, with the following precisions.
▼M2
The manufacturer shall provide evidence to the type-approval authority that the frequency ranges of the 48V motor-generator are the same as or equivalent to those set out in Table 1 or Table 1a.
The efficiency of the 48V motor-generator shall be determined on the basis of measurements at each of the operating points listed in Table 1 or Table 1a.
▼B
The current intensity of the 48V motor-generator at each operating point shall be half the rated current. For each operating point, the voltage and the output current of the 48V motor-generator shall be kept constant during the measurement, with the voltage at 52V.
▼M2
Where the motor-generator is fitted in passenger cars or light commercial vehicles that meet the requirements set out in Article 1(a)(ii), and it is connected directly to the transmission input shaft, i.e. as an integrated starter generator, the rotational frequencies and frequencies of the operating points shall be set in accordance with Table 1a.
▼B
Table 1
|
Operating point i |
Holding time [s] |
Rotational frequency image – nicht separat verfügbar. Quelldokument öffnen |
Frequency of operating points image – nicht separat verfügbar. Quelldokument öffnen |
|
1 |
1 200 |
1 800 |
0,25 |
|
2 |
1 200 |
3 000 |
0,40 |
|
3 |
600 |
6 000 |
0,25 |
|
4 |
300 |
10 000 |
0,10 |
▼M2
Table 1a
Operating points
|
Operating point i |
Holding time [s] |
Rotational frequency ni [min-1] |
Frequency of operating points hi |
|
1 |
1 200 |
950 |
0,30 |
|
2 |
1 200 |
1 250 |
0,50 |
|
3 |
600 |
1 550 |
0,16 |
|
4 |
300 |
1 850 |
0,04 |
▼B
The efficiency of the 48V motor-generator at each operating point i (image – nicht separat verfügbar. Quelldokument öffnen) [%] shall be calculated in accordance with Formula 1.
Formula 1
image – nicht separat verfügbar. Quelldokument öffnen
where, for each operating point i,
|
Ui |
is the voltage [V]; |
|
Ii |
is the current intensity [A]; |
|
Μi |
is the torque [Nm]; |
|
ni |
is the rotational frequency [min-1]. |
For each operating point, the measurements are to be performed at least five times consecutively and the efficiency shall be calculated for each of those measurementsimage – nicht separat verfügbar. Quelldokument öffnenwith j being the index referring to one set of measurements.
For each operating point, the average of those efficienciesimage – nicht separat verfügbar. Quelldokument öffnenshall be calculated.
The efficiency of the 48V motor-generatorimage – nicht separat verfügbar. Quelldokument öffnen[%] shall be calculated in accordance with Formula 2.
Formula 2
image – nicht separat verfügbar. Quelldokument öffnen
where
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the mean efficiency of the 48V motor-generator determined for operating point i [%] |
|
hi |
is the frequency of operating point i, as set out in Table 1. |
2.2. 48V/12V DC/DC converter efficiency
The efficiency of the 48V/12V DC/DC converter shall be determined under the following conditions:
The nominal power of the 48V/12V DC/DC converter shall be the continuous output power certified by the supplier in accordance with the requirements specified in ISO 8854:2012.
The efficiency of the 48V/12V DC/DC converterimage – nicht separat verfügbar. Quelldokument öffnen[%] shall be calculated from the current and voltage intensity measurements according to Formula 3.
Formula 3
image – nicht separat verfügbar. Quelldokument öffnen
where
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the input voltage, which shall be set to 52 [V] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the current intensity measured on the input side [A] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the output voltage, which shall be set to 14,3 [V] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the current intensity measured on the output side, which should be equal to the nominal power of the 48V/12V DC/DC converter divided by the output voltage [A] |
The measurements and efficiency calculations shall be repeated at least five (5) times consecutively.
The average of those efficiencies shall then be the efficiency of the 48V/12V DC/DC converterimage – nicht separat verfügbar. Quelldokument öffnen[%].
2.3. Combined efficiency
The efficiency of the 48V motor generator combined with the 48V/12V DC/DC converterimage – nicht separat verfügbar. Quelldokument öffnen[%] is calculated in accordance with Formula 4.
Formula 4
image – nicht separat verfügbar. Quelldokument öffnen
|
image – nicht separat verfügbar. Quelldokument öffnen : |
is the efficiency of the 48V motor-generator, as determined in point 2.1 [%] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the efficiency of the 48V/12V DC/DC converter, as determined in point 2.2 [%] |
3. CALCULATION OF THE CO2 SAVINGS
3.1. Saved mechanical power
The differenceimage – nicht separat verfügbar. Quelldokument öffnen[W] between the saved mechanical power when using the 48V motor generator combined with the 48V/12V DC/DC converter under real-world conditionsimage – nicht separat verfügbar. Quelldokument öffnenand the saved mechanical power when using the 48V motor generator combined with the 48V/12V DC/DC converter under type-approval conditionsimage – nicht separat verfügbar. Quelldokument öffnenshall be calculated in accordance with Formula 5.
Formula 5
image – nicht separat verfügbar. Quelldokument öffnen
where
image – nicht separat verfügbar. Quelldokument öffnenshall be calculated in accordance with Formula 6 andimage – nicht separat verfügbar. Quelldokument öffnenin accordance with Formula 7.
Formula 6
image – nicht separat verfügbar. Quelldokument öffnen
Formula 7
image – nicht separat verfügbar. Quelldokument öffnen
where,
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the efficiency of the 48V motor-generator combined with the 48V/12V DC/DC converter, as determined in point 2.3 [%] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the power requirement under ‘real-world’ conditions, which is 750 W |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the power requirement under ‘type-approval’ conditions, which is 350 W |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the efficiency of the baseline alternator, which is 67 % |
3.2. Calculation of the CO2 savings
The CO2 savings of the 48V motor-generator combined with the 48V/12V DC/DC converterimage – nicht separat verfügbar. Quelldokument öffnenshall be calculated in accordance with Formula 8.
Formula 8
image – nicht separat verfügbar. Quelldokument öffnen
where,
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the difference between the saved mechanical power under real-world conditions and the saved mechanical power under type-approval conditions, as determined in point 3.1 |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the mean driving speed of the WLTP, which is 46,6 km/h |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the consumption of effective power as specified in Table 2 [l/kWh] |
|
CF |
is the conversion factor as set out in Table 3image – nicht separat verfügbar. Quelldokument öffnen |
▼M1
Table 2
Consumption of effective power
|
Type of engine |
Consumption of effective power (Vpe) [l/kWh] |
|
Petrol/E85 |
0,264 |
|
Petrol/E85 Turbo |
0,280 |
|
Diesel |
0,220 |
|
LPG |
0,342 |
|
LPG Turbo |
0,363 |
|
|
Consumption of effective power (Vpe) [m3/kWh] |
|
CNG (G20) |
0,259 |
|
CNG (G20) Turbo |
0,275 |
Table 3
Fuel conversion factor (CF)
|
Type of fuel |
Conversion factor (CF) [gCO2/l] |
|
Petrol/E85 |
2 330 |
|
Diesel |
2 640 |
|
LPG |
1 629 |
|
|
Conversion factor (CF) [gCO2/m3] |
|
CNG (G20) |
1 795 |
▼B
3.3. Calculation of the uncertainty of the CO2 savings
The uncertainty of the CO2 savings calculated in accordance with point 3.2 shall be quantified.
For this, the following calculations are needed.
First, the standard deviation of the efficiency of the 48V motor-generator at each operating pointimage – nicht separat verfügbar. Quelldokument öffnen[%] shall be calculated in accordance with Formula 9.
Formula 9
image – nicht separat verfügbar. Quelldokument öffnen
where
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the number of measurements j undertaken at each operating point i for the 48V motor-generator efficiency, as referred to in point 2.1 |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the efficiency of the 48V motor-generator calculated for an individual measurement j at operating point i as referred to in point 2.1 [%] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the average efficiency of the 48V motor-generator calculated for an operating point i, as determined in point 2.1 [%] |
Next, the standard deviation of the efficiency of the 48V motor-generatorimage – nicht separat verfügbar. Quelldokument öffnen[%] shall be calculated in accordance with Formula 10.
Formula 10
image – nicht separat verfügbar. Quelldokument öffnen
where
|
image – nicht separat verfügbar. Quelldokument öffnen |
is as determined by Formula 9 [%] |
|
hi |
is the frequency of operating point i, as set out in Table 1. |
Then, the standard deviation of the efficiency of the 48V/12V DC/DC converterimage – nicht separat verfügbar. Quelldokument öffnen[%] shall be calculated in accordance with Formula 11.
Formula 11
image – nicht separat verfügbar. Quelldokument öffnen
where
|
L |
is the number of measurements l undertaken for the 48V/12V DC/DC converter, as referred to in point 2.2 |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the efficiency of the 48V/12V DC/DC converter calculated for an individual measurement l as referred to in point 2.2 [%] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the efficiency of the 48V/12V DC/DC converter, as determined in point 2.2 [%] |
Finally, the uncertainty in the CO2 savingsimage – nicht separat verfügbar. Quelldokument öffnenof the 48V motor-generator combined with the 48V/12V DC/DC converter shall be calculated in accordance with Formula 12 and shall not exceed 30 % of the CO2 savings.
Formula 12
image – nicht separat verfügbar. Quelldokument öffnen
where
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the power requirement under ‘real-world’ conditions, which is 750 W |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the power requirement under type-approval conditions, which is 350 W |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the total efficiency of the 48V motor-generator combined with the 48V/12V DC/DC converter as determined in point 2.3 [%] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the consumption of effective power as specified in Table 2 [l/kWh] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the fuel conversion factor as specified in Table 3image – nicht separat verfügbar. Quelldokument öffnen |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the mean driving speed of the WLTP, which is 46,6 km/h |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is standard deviation of the efficiency of the 48V motor-generator as determined in accordance with Formula 10 [%] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the efficiency of the 48V motor-generator, as determined in point 2.1 [%] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the standard deviation of the efficiency of the 48V/12V DC/DC converter, as determined in accordance with Formula 11 [%] |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the efficiency of the 48V/12V DC/DC converter as determined in point 2.2 [%] |
3.4. Rounding
The CO2 savings image – nicht separat verfügbar. Quelldokument öffnen calculated in accordance with point 3.2 and the uncertainty of the CO2 savings image – nicht separat verfügbar. Quelldokument öffnen calculated in accordance with point 3.3 shall be rounded to a maximum of two decimal places.
Each value used in the calculation of the CO2 savings can be applied unrounded or must be rounded to the minimum number of decimal places which allows the maximum total impact (i.e. combined impact of all rounded values) on the savings to be lower than 0,25 gCO2/km.
3.5. Check against the minimum CO2 savings threshold
The type-approval authority shall ensure for each vehicle version fitted with the 48V motor-generator combined with the 48V/12V DC/DC converter that the minimum threshold criterion as specified in Article 9(1)(b) of Implementing Regulation (EU) No 725/2011 and Implementing Regulation (EU) No 427/2014 is met.
When verifying whether the minimum threshold criterion is met, the type-approval authority shall take into account, in accordance with Formula 13, the CO2 savings determined in point 3.2, the uncertainty determined in point 3.3 and, where applicable, a CO2 correction, in the case of a positive mass difference (Δm) between the 48V motor-generator combined with the 48V/12V DC/DC converter and the baseline alternator.
For the purpose of the positive mass correction, the mass of the baseline alternator shall be set to 7 kg.
The manufacturer shall provide to the type approval authority information on the mass of the 48V motor-generator combined with the 48V/12V DC/DC converter as certified by the supplier.
Formula 13
image – nicht separat verfügbar. Quelldokument öffnen
where,
|
MT |
is 0,5 g CO2/km as specified in Article 9(1)(b) of Implementing Regulation (EU) No 725/2011 and Commission Implementing Regulation (EU) No 427/2014 |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the CO2 savings as determined in point 3.2image – nicht separat verfügbar. Quelldokument öffnen |
|
image – nicht separat verfügbar. Quelldokument öffnen |
uncertainty of the total CO2 savings as determined in point 3.3image – nicht separat verfügbar. Quelldokument öffnen |
|
image – nicht separat verfügbar. Quelldokument öffnen |
CO2 correction, in the case of a positive mass difference (Δm) [kg] between the 48V motor-generator combined with the 48V/12V DC/DC converter and the baseline alternator, calculated in accordance with Table 4:image – nicht separat verfügbar. Quelldokument öffnen |
▼M1
Table 4
CO2 correction due to the extra mass
|
Petrol/E85 (ΔCO2mP) [g CO2/km] |
0,0277•Δm |
|
Diesel (ΔCO2mD) [g CO2/km] |
0,0383•Δm |
|
LPG (ΔCO2mLPG) [g CO2/km] |
0,0251•Δm |
|
CNG (ΔCO2mCNG(G20)) [g CO2/km] |
0,0209•Δm |
▼B
4. CERTIFICATION OF CO2 SAVINGS
The CO2 savings to be certified by the type-approval authority in accordance with Article 11 of Implementing Regulations (EU) No 725/2011 or (EU) No 427/2014image – nicht separat verfügbar. Quelldokument öffnenare those calculated in accordance with Formula 14. The CO2 savings shall be recorded in the type approval certificate for each vehicle version fitted with the 48V motor-generator combined with the 48V/12V DC/DC converter.
Formula 14
image – nicht separat verfügbar. Quelldokument öffnen
where,
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the CO2 savings as determined in accordance with Formula 8 under point 3.2image – nicht separat verfügbar. Quelldokument öffnen |
|
image – nicht separat verfügbar. Quelldokument öffnen |
is the uncertainty in the CO2 savings of the 48V motor-generator combined with the 48V/12V DC/DC converter calculated in accordance with Formula 12 under point 3.3image – nicht separat verfügbar. Quelldokument öffnen |